Re: Workflow container not set some times- Intermittent Issue
>If there is bug in code then it should be the on-going issue, this occurs very rarely.Don' be so sure.There may be a bug that only expresses itself sometimes, when the conditions are just so.I've...
View ArticleRe: Email Expressions are Blank in Sub-workflow Created for MDG
Hi Rick, Although I have always seen CR_CREATOR_NAME (with my ID as the Value) in the WF Technical Log, this is not something I created. I assumed it was somehow provided by BUS2250 or the system:So...
View ArticleDunning letter (email) PDF attachment or body of email
Hi experts, What is the industry practice for dunning letters when sent via email? Attach them as a pdf to the email, or add all the content of the dunning letter to the body of the email to make it...
View ArticleRe: complete material of pp configuration with screen shots
hello sankaran -sir , if possible , could you send that pp configuration document to my inbox - arghyaray@gmail.com thanks in advance , regards arghya
View ArticleRe: Adjust stock in WM
Hi, When you have posted 101 movement , you have adjusted the stock in WM but when you posted 102, you haven't adjusted the stocks in WM. Please created a Transfer Order either with reference to the...
View ArticleRe: Error message- M7 021- Deficit of VC unrestricted use 5 PK: material...
I thought the screen shot attached showed Unit of entry as 35 PK.However, we are trying to move 35 PK from consignment to own stock. Thanks,Shilpa
View ArticleRe: Work center view from PP - Enhance Plan values VGW01, VGW02, VGW03, etc....
Hi all, it´s really curious why the plan fields (VGW01, VGW02, ...) are not extracted in the DataSource 2LIS_04_P_ARBPL. The VGE values are available as standard fields... I have tested the Outbound...
View ArticleINTERNET CONNECTION NOT DETECTED message with Crystal Reports 2011
Hello: We upgrade from SQL 3008 R2 to SQL 2012 SP1. Had trouble with Crystal Reports not opening reports. Information on the internet indicated that you had to reinstall Crystal Reports after...
View ArticleRe: I can not access the web platform
Hi Yair,sorry I'm not a basis, i read the issue should be in lack of authorizazion permissions e.g. you don't not have access to the C:\Winnt\System32\Inetsrv directory see...
View ArticleRe: Upload of GL balances in mid year go live
I am making an assumption that the fiscal year is a calendar based year for my answer. If it is not, adjust acccordingly, but the principles remain the same. 1. You must load in the ending...
View ArticleRe: Starting now: No more points for likes on comments/replies
I am really enjoying the comments to this announcement... :-) Laure could complete a few more such missions as this one by using the same strategy on further SCN contribution types as far as I (and the...
View ArticleRe: Equipment PRT long text not carried over to a routing
Hi Gurus, Is there a solution to this issue?If this is not an issue that's totally fine. If it's standard SAP behavior - that OK. All I want to know is - if the Master PRT text is a static data (just...
View ArticleRe: how to send notifications when there any changes in Metapedia terms
Hi Vamsi, There are no notifications for those type of changes. The changes should show up in the results of the terms. Only Data Insight has notifications that can be sent out. Thanks,BW
View ArticleMessage could not be processed error
Hello Experts, We are on PI 7.31 SP7 java only stack. Our scenario is a File to IDOC with BPM process. Here are the steps I did so far. 1. Completed the design objects 2. Completed the configuration...
View ArticleRe: DTW Login Failure
I've had the same problem. To resolve it, you must uninstall and re-install the DI API, not just DTW. The DTW install wizard doesn't allow you to set the license server, the DI API install wizard does...
View ArticleRe: Get domain value range dynamically
It should be possible since the system is using it for value helps, maybe you will find the answer there.
View ArticleRe: BOE Metadata Integrator not collecting metadata from specified folder
Hi BODS, Take a look at the log that has been created for the integrator run. It should give you an idea of whats going on. Look for [W] and [E] in the logs. Maybe you could post them here or attach...
View ArticleRe: WD Application Configuration HAP_AC_MAIN_DOC overwrites standard settings
Hi Chaitanya,thank you for your reply. I had a look on this information too. It works fine as long as you directly call WD applications. In my case I have a standard FPM application with its...
View ArticleRe: ora 12560 TNS Protocol Adapter error after upgraded the oracle from...
Hello SantoshI don't think that could be reason for this error.The last option I can suggest you is this.Kill all processes running under orasid or if possible restart the server.Once done connect to...
View Article